-- AT-PLUGGABLE-DIAGNOSTICS-MIB, Allied Telesis enterprise MIB:
-- Diagnostic objects related to Optical Pluggable modules.
--
-- Copyright (c) 2015 by Allied Telesis, Inc.
-- All rights reserved.
--
-- ============================================================================

AT-PLUGGABLE-DIAGNOSTICS-MIB DEFINITIONS ::= BEGIN

IMPORTS
    DisplayStringUnsized
        FROM AT-SMI-MIB
    sysinfo
        FROM AT-SYSINFO-MIB
    Integer32, OBJECT-TYPE, MODULE-IDENTITY
        FROM SNMPv2-SMI
    InterfaceIndex
        FROM IF-MIB;


atPluggableDiag MODULE-IDENTITY
    LAST-UPDATED    "201507170000Z"
    ORGANIZATION    "Allied Telesis, Inc"
    CONTACT-INFO    "http://www.alliedtelesis.com"
    DESCRIPTION
        "The AT Pluggbale Diagnostics MIB contains objects to retrieve the standard
        diagnostic information from installed SFP modules."
    REVISION        "201507170000Z"
    DESCRIPTION     "Initial revision"
    ::= { sysinfo 28 }

----------------------------------------------------------------
-- The Digital Diagnostic monitoring for optical pluggables
----------------------------------------------------------------

atPluggableDiagTable OBJECT IDENTIFIER ::= { atPluggableDiag 1 }

----------------------------------------------------------------
-- Temperature table for Digital Diagnostic monitoring
----------------------------------------------------------------

atPluggableDiagTempTable OBJECT-TYPE
    SYNTAX        SEQUENCE OF AtPluggableDiagTempEntry
    MAX-ACCESS    not-accessible
    STATUS        current
    DESCRIPTION
           "A table of information regarding the various temperature parameters observed
           as a part of Digital diagnostics monitoring, for all the optical pluggables
           installed in the devices."
    ::= { atPluggableDiagTable 1 }

atPluggableDiagTempEntry OBJECT-TYPE
    SYNTAX        AtPluggableDiagTempEntry
    MAX-ACCESS    not-accessible
    STATUS        current
    DESCRIPTION
        "The information about various temperature parameters of pluggables
        such as current status reading, current alarm status, higher and lower
        alarm threshold, current warning, higher and lower warning threshold."
    INDEX { atPluggableDiagTempIfIndex, atPluggableDiagTempChannel }
    ::= { atPluggableDiagTempTable 1 }

AtPluggableDiagTempEntry ::= SEQUENCE {
      atPluggableDiagTempIfIndex            InterfaceIndex,
      atPluggableDiagTempChannel            Integer32,
      atPluggableDiagTempStatusReading      Integer32,
      atPluggableDiagTempCurrentAlarm       OCTET STRING,
      atPluggableDiagTempAlarmMax           Integer32,
      atPluggableDiagTempAlarmMin           Integer32,
      atPluggableDiagTempCurrentWarning     OCTET STRING,
      atPluggableDiagTempWarningMax         Integer32,
      atPluggableDiagTempWarningMin         Integer32 }

atPluggableDiagTempIfIndex OBJECT-TYPE
    SYNTAX        InterfaceIndex
    MAX-ACCESS    not-accessible
    STATUS        current
    DESCRIPTION
        "The ifindex of the pluggable."
    ::= { atPluggableDiagTempEntry 1 }

atPluggableDiagTempChannel OBJECT-TYPE
    SYNTAX        Integer32(1..16)
    MAX-ACCESS    not-accessible
    STATUS        current
    DESCRIPTION
        "The channel number of the pluggable."
    ::= { atPluggableDiagTempEntry 2 }

atPluggableDiagTempStatusReading OBJECT-TYPE
    SYNTAX        Integer32
    UNITS         "0.001 degree C"
    MAX-ACCESS    read-only
    STATUS        current
    DESCRIPTION
        "The current temperature status reading."
    ::= { atPluggableDiagTempEntry 3 }

atPluggableDiagTempCurrentAlarm OBJECT-TYPE
    SYNTAX        OCTET STRING
    MAX-ACCESS    read-only
    STATUS        current
    DESCRIPTION
        "The current temperature alarm reading."
    ::= { atPluggableDiagTempEntry 4 }

atPluggableDiagTempAlarmMax OBJECT-TYPE
    SYNTAX        Integer32
    UNITS         "0.001 degree C"
    MAX-ACCESS    read-only
    STATUS        current
    DESCRIPTION
        "The maximum temperature alarm threshold value."
    ::= { atPluggableDiagTempEntry 5 }

atPluggableDiagTempAlarmMin OBJECT-TYPE
    SYNTAX        Integer32
    UNITS         "0.001 degree C"
    MAX-ACCESS    read-only
    STATUS        current
    DESCRIPTION
        "The minimum temperature alarm threshold value."
    ::= { atPluggableDiagTempEntry 6 }

atPluggableDiagTempCurrentWarning OBJECT-TYPE
    SYNTAX        OCTET STRING
    MAX-ACCESS    read-only
    STATUS        current
    DESCRIPTION
        "The current temperature warnings."
    ::= { atPluggableDiagTempEntry 7 }

atPluggableDiagTempWarningMax OBJECT-TYPE
    SYNTAX        Integer32
    UNITS         "0.001 degree C"
    MAX-ACCESS    read-only
    STATUS        current
    DESCRIPTION
        "The maximum temperature warning threshold value."
    ::= { atPluggableDiagTempEntry 8 }

atPluggableDiagTempWarningMin OBJECT-TYPE
    SYNTAX        Integer32
    UNITS         "0.001 degree C"
    MAX-ACCESS    read-only
    STATUS        current
    DESCRIPTION
        "The minimum temperature warning threshold value."
    ::= { atPluggableDiagTempEntry 9 }

----------------------------------------------------------------
-- Voltage (Vcc) table for Digital Diagnostic monitoring
----------------------------------------------------------------

atPluggableDiagVccTable OBJECT-TYPE
    SYNTAX        SEQUENCE OF AtPluggableDiagVccEntry
    MAX-ACCESS    not-accessible
    STATUS        current
    DESCRIPTION
        "A table of information regarding the various Voltage (Vcc) parameters observed
        as a part of Digital diagnostics monitoring, for all the optical pluggables
        installed in the devices."
    ::= { atPluggableDiagTable 2 }

atPluggableDiagVccEntry OBJECT-TYPE
    SYNTAX        AtPluggableDiagVccEntry
    MAX-ACCESS    not-accessible
    STATUS        current
    DESCRIPTION
        "The information about various Voltage (Vcc) parameters of pluggables
        such as current status reading, current alarm status, higher and lower
        alarm threshold, current warning, higher and lower warning threshold."
    INDEX { atPluggableDiagVccIfIndex, atPluggableDiagVccChannel }
    ::= { atPluggableDiagVccTable 1 }

AtPluggableDiagVccEntry ::= SEQUENCE {
      atPluggableDiagVccIfIndex             InterfaceIndex,
      atPluggableDiagVccChannel             Integer32,
      atPluggableDiagVccStatusReading       Integer32,
      atPluggableDiagVccCurrentAlarm        OCTET STRING,
      atPluggableDiagVccAlarmMax            Integer32,
      atPluggableDiagVccAlarmMin            Integer32,
      atPluggableDiagVccCurrentWarning      OCTET STRING,
      atPluggableDiagVccWarningMax          Integer32,
      atPluggableDiagVccWarningMin          Integer32 }

atPluggableDiagVccIfIndex OBJECT-TYPE
    SYNTAX        InterfaceIndex
    MAX-ACCESS    not-accessible
    STATUS        current
    DESCRIPTION
        "The ifindex of the pluggable."
    ::= { atPluggableDiagVccEntry 1 }

atPluggableDiagVccChannel OBJECT-TYPE
    SYNTAX        Integer32(1..16)
    MAX-ACCESS    not-accessible
    STATUS        current
    DESCRIPTION
        "The channel number of the pluggable."
    ::= { atPluggableDiagVccEntry 2 }

atPluggableDiagVccStatusReading OBJECT-TYPE
    SYNTAX        Integer32
    UNITS         "0.0001 volts"
    MAX-ACCESS    read-only
    STATUS        current
    DESCRIPTION
        "The current Voltage (Vcc) status reading."
    ::= { atPluggableDiagVccEntry 3 }

atPluggableDiagVccCurrentAlarm OBJECT-TYPE
    SYNTAX        OCTET STRING
    MAX-ACCESS    read-only
    STATUS        current
    DESCRIPTION
        "The current Voltage (Vcc) alarm reading."
    ::= { atPluggableDiagVccEntry 4 }

atPluggableDiagVccAlarmMax OBJECT-TYPE
    SYNTAX        Integer32
    UNITS         "0.0001 volts"
    MAX-ACCESS    read-only
    STATUS        current
    DESCRIPTION
        "The maximum Voltage (Vcc) alarm threshold value."
    ::= { atPluggableDiagVccEntry 5 }

atPluggableDiagVccAlarmMin OBJECT-TYPE
    SYNTAX        Integer32
    UNITS         "0.0001 volts"
    MAX-ACCESS    read-only
    STATUS        current
    DESCRIPTION
        "The minimum Voltage (Vcc) alarm threshold value."
    ::= { atPluggableDiagVccEntry 6 }

atPluggableDiagVccCurrentWarning OBJECT-TYPE
    SYNTAX        OCTET STRING
    MAX-ACCESS    read-only
    STATUS        current
    DESCRIPTION
        "The current Voltage (Vcc) warnings."
    ::= { atPluggableDiagVccEntry 7 }

atPluggableDiagVccWarningMax OBJECT-TYPE
    SYNTAX        Integer32
    UNITS         "0.0001 volts"
    MAX-ACCESS    read-only
    STATUS        current
    DESCRIPTION
        "The maximum Voltage (Vcc) warning threshold value."
    ::= { atPluggableDiagVccEntry 8 }

atPluggableDiagVccWarningMin OBJECT-TYPE
    SYNTAX        Integer32
    UNITS         "0.0001 volts"
    MAX-ACCESS    read-only
    STATUS        current
    DESCRIPTION
        "The minimum Voltage (Vcc) warning threshold value."
    ::= { atPluggableDiagVccEntry 9 }

----------------------------------------------------------------
-- Tx Bias Current (mA) table for Digital Diagnostic monitoring
----------------------------------------------------------------

atPluggableDiagTxBiasTable OBJECT-TYPE
    SYNTAX        SEQUENCE OF AtPluggableDiagTxBiasEntry
    MAX-ACCESS    not-accessible
    STATUS        current
    DESCRIPTION
        "A table of information regarding the various Tx Bias Current (mA)
        parameters observed as a part of Digital diagnostics monitoring,
        for all the optical pluggables installed in the devices."
    ::= { atPluggableDiagTable 3 }

atPluggableDiagTxBiasEntry OBJECT-TYPE
    SYNTAX        AtPluggableDiagTxBiasEntry
    MAX-ACCESS    not-accessible
    STATUS        current
    DESCRIPTION
        "The information about various Tx Bias Current (mA)
        parameters of pluggables such as current status reading,
        current alarm status, higher and lower alarm threshold,
        current warning, higher and lower warning threshold."
    INDEX { atPluggableDiagTxBiasIfIndex, atPluggableDiagTxBiasChannel }
    ::= { atPluggableDiagTxBiasTable 1 }

AtPluggableDiagTxBiasEntry ::= SEQUENCE {
      atPluggableDiagTxBiasIfIndex          InterfaceIndex,
      atPluggableDiagTxBiasChannel          Integer32,
      atPluggableDiagTxBiasStatusReading    Integer32,
      atPluggableDiagTxBiasCurrentAlarm     OCTET STRING,
      atPluggableDiagTxBiasAlarmMax         Integer32,
      atPluggableDiagTxBiasAlarmMin         Integer32,
      atPluggableDiagTxBiasCurrentWarning   OCTET STRING,
      atPluggableDiagTxBiasWarningMax       Integer32,
      atPluggableDiagTxBiasWarningMin       Integer32 }

atPluggableDiagTxBiasIfIndex OBJECT-TYPE
    SYNTAX        InterfaceIndex
    MAX-ACCESS    not-accessible
    STATUS        current
    DESCRIPTION
        "The ifindex of the pluggable."
    ::= { atPluggableDiagTxBiasEntry 1 }

atPluggableDiagTxBiasChannel OBJECT-TYPE
    SYNTAX        Integer32(1..16)
    MAX-ACCESS    not-accessible
    STATUS        current
    DESCRIPTION
        "The channel number of the pluggable."
    ::= { atPluggableDiagTxBiasEntry 2 }

atPluggableDiagTxBiasStatusReading OBJECT-TYPE
    SYNTAX        Integer32
    UNITS         "0.001 mA"
    MAX-ACCESS    read-only
    STATUS        current
    DESCRIPTION
        "The current Tx Bias (mA) status reading."
    ::= { atPluggableDiagTxBiasEntry 3 }

atPluggableDiagTxBiasCurrentAlarm OBJECT-TYPE
    SYNTAX        OCTET STRING
    MAX-ACCESS    read-only
    STATUS        current
    DESCRIPTION
        "The current Tx Bias (mA) alarm reading."
    ::= { atPluggableDiagTxBiasEntry 4 }

atPluggableDiagTxBiasAlarmMax OBJECT-TYPE
    SYNTAX        Integer32
    UNITS         "0.001 mA"
    MAX-ACCESS    read-only
    STATUS        current
    DESCRIPTION
        "The maximum Tx Bias (mA) alarm threshold value."
    ::= { atPluggableDiagTxBiasEntry 5 }

atPluggableDiagTxBiasAlarmMin OBJECT-TYPE
    SYNTAX        Integer32
    UNITS         "0.001 mA"
    MAX-ACCESS    read-only
    STATUS        current
    DESCRIPTION
        "The minimum Tx Bias (mA) alarm threshold value."
    ::= { atPluggableDiagTxBiasEntry 6 }

atPluggableDiagTxBiasCurrentWarning OBJECT-TYPE
    SYNTAX        OCTET STRING
    MAX-ACCESS    read-only
    STATUS        current
    DESCRIPTION
        "The current Tx Bias (mA) warnings."
    ::= { atPluggableDiagTxBiasEntry 7 }

atPluggableDiagTxBiasWarningMax OBJECT-TYPE
    SYNTAX        Integer32
    UNITS         "0.001 mA"
    MAX-ACCESS    read-only
    STATUS        current
    DESCRIPTION
        "The maximum Tx Bias (mA) warning threshold value."
    ::= { atPluggableDiagTxBiasEntry 8 }

atPluggableDiagTxBiasWarningMin OBJECT-TYPE
    SYNTAX        Integer32
    UNITS         "0.001 mA"
    MAX-ACCESS    read-only
    STATUS        current
    DESCRIPTION
        "The minimum Tx Bias (mA) warning threshold value."
    ::= { atPluggableDiagTxBiasEntry 9 }

----------------------------------------------------------------
-- Tx Power (mW) table for Digital Diagnostic monitoring
----------------------------------------------------------------

atPluggableDiagTxPowerTable OBJECT-TYPE
    SYNTAX        SEQUENCE OF AtPluggableDiagTxPowerEntry
    MAX-ACCESS    not-accessible
    STATUS        current
    DESCRIPTION
        "A table of information regarding the various Tx Power (mW)
        parameters observed as a part of Digital diagnostics monitoring,
        for all the optical pluggables installed in the devices."
    ::= { atPluggableDiagTable 4 }

atPluggableDiagTxPowerEntry OBJECT-TYPE
    SYNTAX        AtPluggableDiagTxPowerEntry
    MAX-ACCESS    not-accessible
    STATUS        current
    DESCRIPTION
        "The information about various Tx Power (mW)
        parameters of pluggables such as current status reading,
        current alarm status, higher and lower alarm threshold,
        current warning, higher and lower warning threshold."
    INDEX { atPluggableDiagTxPowerIfIndex, atPluggableDiagTxPowerChannel }
    ::= { atPluggableDiagTxPowerTable 1 }

AtPluggableDiagTxPowerEntry ::= SEQUENCE {
      atPluggableDiagTxPowerIfIndex         InterfaceIndex,
      atPluggableDiagTxPowerChannel         Integer32,
      atPluggableDiagTxPowerStatusReading   Integer32,
      atPluggableDiagTxPowerCurrentAlarm    OCTET STRING,
      atPluggableDiagTxPowerAlarmMax        Integer32,
      atPluggableDiagTxPowerAlarmMin        Integer32,
      atPluggableDiagTxPowerCurrentWarning  OCTET STRING,
      atPluggableDiagTxPowerWarningMax      Integer32,
      atPluggableDiagTxPowerWarningMin      Integer32 }

atPluggableDiagTxPowerIfIndex OBJECT-TYPE
    SYNTAX        InterfaceIndex
    MAX-ACCESS    not-accessible
    STATUS        current
    DESCRIPTION
        "The ifindex of the pluggable."
    ::= { atPluggableDiagTxPowerEntry 1 }

atPluggableDiagTxPowerChannel OBJECT-TYPE
    SYNTAX        Integer32(1..16)
    MAX-ACCESS    not-accessible
    STATUS        current
    DESCRIPTION
        "The channel number of the pluggable."
    ::= { atPluggableDiagTxPowerEntry 2 }

atPluggableDiagTxPowerStatusReading OBJECT-TYPE
    SYNTAX        Integer32
    UNITS         "0.0001 mW"
    MAX-ACCESS    read-only
    STATUS        current
    DESCRIPTION
        "The current Tx Power (mW) status reading."
    ::= { atPluggableDiagTxPowerEntry 3 }

atPluggableDiagTxPowerCurrentAlarm OBJECT-TYPE
    SYNTAX        OCTET STRING
    MAX-ACCESS    read-only
    STATUS        current
    DESCRIPTION
        "The current Tx Power (mW) alarm reading."
    ::= { atPluggableDiagTxPowerEntry 4 }

atPluggableDiagTxPowerAlarmMax OBJECT-TYPE
    SYNTAX        Integer32
    UNITS         "0.0001 mW"
    MAX-ACCESS    read-only
    STATUS        current
    DESCRIPTION
        "The maximum Tx Power (mW) alarm threshold value."
    ::= { atPluggableDiagTxPowerEntry 5 }

atPluggableDiagTxPowerAlarmMin OBJECT-TYPE
    SYNTAX        Integer32
    UNITS         "0.0001 mW"
    MAX-ACCESS    read-only
    STATUS        current
    DESCRIPTION
        "The minimum Tx Power (mW) alarm threshold value."
    ::= { atPluggableDiagTxPowerEntry 6 }

atPluggableDiagTxPowerCurrentWarning OBJECT-TYPE
    SYNTAX        OCTET STRING
    MAX-ACCESS    read-only
    STATUS        current
    DESCRIPTION
        "The current Tx Power (mW) warnings."
    ::= { atPluggableDiagTxPowerEntry 7 }

atPluggableDiagTxPowerWarningMax OBJECT-TYPE
    SYNTAX        Integer32
    UNITS         "0.0001 mW"
    MAX-ACCESS    read-only
    STATUS        current
    DESCRIPTION
        "The maximum Tx Power (mW) warning threshold value."
    ::= { atPluggableDiagTxPowerEntry 8 }

atPluggableDiagTxPowerWarningMin OBJECT-TYPE
    SYNTAX        Integer32
    UNITS         "0.0001 mW"
    MAX-ACCESS    read-only
    STATUS        current
    DESCRIPTION
        "The minimum Tx Power (mW) warning threshold value."
    ::= { atPluggableDiagTxPowerEntry 9 }

----------------------------------------------------------------
-- Rx Power (mW) table for Digital Diagnostic monitoring
----------------------------------------------------------------

atPluggableDiagRxPowerTable OBJECT-TYPE
    SYNTAX        SEQUENCE OF AtPluggableDiagRxPowerEntry
    MAX-ACCESS    not-accessible
    STATUS        current
    DESCRIPTION
        "A table of information regarding the various Rx Power (mW)
        parameters observed as a part of Digital diagnostics monitoring,
        for all the optical pluggables installed in the devices."
    ::= { atPluggableDiagTable 5 }

atPluggableDiagRxPowerEntry OBJECT-TYPE
    SYNTAX        AtPluggableDiagRxPowerEntry
    MAX-ACCESS    not-accessible
    STATUS        current
    DESCRIPTION
        "The information about various Rx Power (mW)
        parameters of pluggables such as current status reading,
        current alarm status, higher and lower alarm threshold,
        current warning, higher and lower warning threshold."
    INDEX { atPluggableDiagRxPowerIfIndex, atPluggableDiagRxPowerChannel }
    ::= { atPluggableDiagRxPowerTable 1 }

AtPluggableDiagRxPowerEntry ::= SEQUENCE {
      atPluggableDiagRxPowerIfIndex         InterfaceIndex,
      atPluggableDiagRxPowerChannel         Integer32,
      atPluggableDiagRxPowerStatusReading   Integer32,
      atPluggableDiagRxPowerCurrentAlarm    OCTET STRING,
      atPluggableDiagRxPowerAlarmMax        Integer32,
      atPluggableDiagRxPowerAlarmMin        Integer32,
      atPluggableDiagRxPowerCurrentWarning  OCTET STRING,
      atPluggableDiagRxPowerWarningMax      Integer32,
      atPluggableDiagRxPowerWarningMin      Integer32 }

atPluggableDiagRxPowerIfIndex OBJECT-TYPE
    SYNTAX        InterfaceIndex
    MAX-ACCESS    not-accessible
    STATUS        current
    DESCRIPTION
        "The ifindex of the pluggable."
    ::= { atPluggableDiagRxPowerEntry 1 }

atPluggableDiagRxPowerChannel OBJECT-TYPE
    SYNTAX        Integer32(1..16)
    MAX-ACCESS    not-accessible
    STATUS        current
    DESCRIPTION
        "The channel number of the pluggable."
    ::= { atPluggableDiagRxPowerEntry 2 }

atPluggableDiagRxPowerStatusReading OBJECT-TYPE
    SYNTAX        Integer32
    UNITS         "0.0001 mW"
    MAX-ACCESS    read-only
    STATUS        current
    DESCRIPTION
        "The current Rx Power (mW) status reading."
    ::= { atPluggableDiagRxPowerEntry 3 }

atPluggableDiagRxPowerCurrentAlarm OBJECT-TYPE
    SYNTAX        OCTET STRING
    MAX-ACCESS    read-only
    STATUS        current
    DESCRIPTION
        "The current Rx Power (mW) alarm reading."
    ::= { atPluggableDiagRxPowerEntry 4 }

atPluggableDiagRxPowerAlarmMax OBJECT-TYPE
    SYNTAX        Integer32
    UNITS         "0.0001 mW"
    MAX-ACCESS    read-only
    STATUS        current
    DESCRIPTION
        "The maximum Rx Power (mW) alarm threshold value."
    ::= { atPluggableDiagRxPowerEntry 5 }

atPluggableDiagRxPowerAlarmMin OBJECT-TYPE
    SYNTAX        Integer32
    UNITS         "0.0001 mW"
    MAX-ACCESS    read-only
    STATUS        current
    DESCRIPTION
        "The minimum Rx Power (mW) alarm threshold value."
    ::= { atPluggableDiagRxPowerEntry 6 }

atPluggableDiagRxPowerCurrentWarning OBJECT-TYPE
    SYNTAX        OCTET STRING
    MAX-ACCESS    read-only
    STATUS        current
    DESCRIPTION
        "The current Rx Power (mW) warnings."
    ::= { atPluggableDiagRxPowerEntry 7 }

atPluggableDiagRxPowerWarningMax OBJECT-TYPE
    SYNTAX        Integer32
    UNITS         "0.0001 mW"
    MAX-ACCESS    read-only
    STATUS        current
    DESCRIPTION
        "The maximum Rx Power (mW) warning threshold value."
    ::= { atPluggableDiagRxPowerEntry 8 }

atPluggableDiagRxPowerWarningMin OBJECT-TYPE
    SYNTAX        Integer32
    UNITS         "0.0001 mW"
    MAX-ACCESS    read-only
    STATUS        current
    DESCRIPTION
        "The minimum Rx Power (mW) warning threshold value."
    ::= { atPluggableDiagRxPowerEntry 9 }

-----------------------------------------------------------------------
-- Rx Loss of Signal (LOS) table for Digital Diagnostic monitoring
-----------------------------------------------------------------------

atPluggableDiagRxLosTable OBJECT-TYPE
    SYNTAX        SEQUENCE OF AtPluggableDiagRxLosEntry
    MAX-ACCESS    not-accessible
    STATUS        current
    DESCRIPTION
        "A table of information regarding the Rx Loss of Singal (Los)
        parameters observed as a part of Digital diagnostics monitoring,
        for all the optical pluggables installed in the devices."
    ::= { atPluggableDiagTable 6 }

atPluggableDiagRxLosEntry OBJECT-TYPE
    SYNTAX        AtPluggableDiagRxLosEntry
    MAX-ACCESS    not-accessible
    STATUS        current
    DESCRIPTION
        "The information about various Rx Loss of Singal (Los) parameters
        of pluggables such as current status reading."
    INDEX { atPluggableDiagRxLosIfIndex, atPluggableDiagRxLosChannel }
    ::= { atPluggableDiagRxLosTable 1 }

AtPluggableDiagRxLosEntry ::= SEQUENCE {
      atPluggableDiagRxLosIfIndex           InterfaceIndex,
      atPluggableDiagRxLosChannel           Integer32,
      atPluggableDiagRxLosStatusReading     OCTET STRING }

atPluggableDiagRxLosIfIndex OBJECT-TYPE
    SYNTAX        InterfaceIndex
    MAX-ACCESS    not-accessible
    STATUS        current
    DESCRIPTION
        "The ifindex of the pluggable."
    ::= { atPluggableDiagRxLosEntry 1 }

atPluggableDiagRxLosChannel OBJECT-TYPE
    SYNTAX        Integer32(1..16)
    MAX-ACCESS    not-accessible
    STATUS        current
    DESCRIPTION
        "The channel number of the pluggable."
    ::= { atPluggableDiagRxLosEntry 2 }

atPluggableDiagRxLosStatusReading OBJECT-TYPE
    SYNTAX        OCTET STRING
    MAX-ACCESS    read-only
    STATUS        current
    DESCRIPTION
        "The current Rx Los status reading."
    ::= { atPluggableDiagRxLosEntry 3 }

END