	ARRIS-D5-ENT-SENSOR-THRESH-MIB DEFINITIONS ::= BEGIN
 
		IMPORTS
			packetport, cm110, tcm, ttm, ttp, 
			cmtsMSAS, cmts1500, cmtsC3, cmtsC4, cmtsCommon, 
			mrcController, arrisGlobalAccessMib, arrisGlobalAccessProductUas, arrisD5UEQam			
				FROM ARRIS-MIB			
			entPhysicalIndex, entityPhysicalGroup			
				FROM ENTITY-MIB			
			entPhySensorType, entPhySensorScale, entPhySensorPrecision, entPhySensorValue, entPhySensorOperStatus, 
			entPhySensorUnitsDisplay, entPhySensorValueTimeStamp, entPhySensorValueUpdateRate, entitySensorCompliance, entitySensorValueGroup, 
			entPhySensorEntry			
				FROM ENTITY-SENSOR-MIB			
			OBJECT-GROUP, MODULE-COMPLIANCE			
				FROM SNMPv2-CONF			
			Integer32, OBJECT-TYPE, MODULE-IDENTITY			
				FROM SNMPv2-SMI;
	
	
		-- 1.3.6.1.4.1.4115.1.7.1.4
		arrisEntSensorThreshMIB MODULE-IDENTITY 
			LAST-UPDATED "200710100000Z" -- 10th Oct 2007
			ORGANIZATION 
				"Arris"
			CONTACT-INFO 
				"Cindy Tromer
						Postal: Arris Interactive
						        3871 Lakefield Drive
						        Suite 300
						        Suwanee, GA 30024-1242
						        U.S.A.
						Phone:  +1 770 622 8679
						E-mail: cindy.tromer@arrisi.com
						
						Initial MIB creator: Cindy Tromer
						Postal: Arris Interactive
						        3871 Lakefield Drive
						        Suite 300
						        Suwanee, GA 30024-1242
						        U.S.A.
						Phone:  +1 770 622 8679
						E-mail: cindy.tromer@arrisi.com
				"
			DESCRIPTION 
				"This is the extension Module to rfc3433 ENTITY-SENSOR-MIB."
			::= { arrisD5UEQam 4 }

		
	
	
--
-- Node definitions
--
	
		-- 1.3.6.1.4.1.4115.1.7.1.4.1
		entThreshObjects OBJECT IDENTIFIER ::= { arrisEntSensorThreshMIB 1 }

		
		-- 1.3.6.1.4.1.4115.1.7.1.4.1.1
		entThreshTable OBJECT-TYPE
			SYNTAX SEQUENCE OF EntThreshEntry
			MAX-ACCESS not-accessible
			STATUS current
			DESCRIPTION
				"This table contains one row per physical sensor. 
				
				Each row contains the set of thresholds maintained
				for each pyhsical sensor."
			::= { entThreshObjects 1 }

		
		-- 1.3.6.1.4.1.4115.1.7.1.4.1.1.1
		entThreshEntry OBJECT-TYPE
			SYNTAX EntThreshEntry
			MAX-ACCESS not-accessible
			STATUS current
			DESCRIPTION
				"The threshold information for a particular 
				physical sensor.
				
				An entry in this table describes the upper and lower warning
				thresholds, as well as the upper and lower fatal thresholds."
			AUGMENTS { entPhySensorEntry }
			::= { entThreshTable 1 }

		
		EntThreshEntry ::=
			SEQUENCE { 
				entLowerWarnThresh
					Integer32,
				entUpperWarnThresh
					Integer32,
				entLowerFatalThresh
					Integer32,
				entUpperFatalThresh
					Integer32
			 }

		-- 1.3.6.1.4.1.4115.1.7.1.4.1.1.1.1
		entLowerWarnThresh OBJECT-TYPE
			SYNTAX Integer32
			MAX-ACCESS read-write
			STATUS current
			DESCRIPTION
				"The lower warning threshold for a physical sensor. 
				When a sensor value goes below this threshold, the 
				system will continue to operate, but the craftperson
				should evaluate the problem. "
			::= { entThreshEntry 1 }

		
		-- 1.3.6.1.4.1.4115.1.7.1.4.1.1.1.2
		entUpperWarnThresh OBJECT-TYPE
			SYNTAX Integer32
			MAX-ACCESS read-write
			STATUS current
			DESCRIPTION
				"The upper warning threshold for a physical sensor. 
				When a sensor value goes above this threshold, the 
				system will continue to operate, but the craftperson
				should evaluate the problem. "
			::= { entThreshEntry 2 }

		
		-- 1.3.6.1.4.1.4115.1.7.1.4.1.1.1.3
		entLowerFatalThresh OBJECT-TYPE
			SYNTAX Integer32
			MAX-ACCESS read-write
			STATUS current
			DESCRIPTION
				"The lower fatal threshold for a physical sensor. 
				When a sensor value goes below this threshold, the 
				system will shutdown."
			::= { entThreshEntry 3 }

		
		-- 1.3.6.1.4.1.4115.1.7.1.4.1.1.1.4
		entUpperFatalThresh OBJECT-TYPE
			SYNTAX Integer32
			MAX-ACCESS read-write
			STATUS current
			DESCRIPTION
				"The upper fatal threshold for a physical sensor. 
				When a sensor value goes above this threshold, the 
				system will shutdown."
			::= { entThreshEntry 4 }

		
		-- 1.3.6.1.4.1.4115.1.7.1.4.2
		entThreshConformance OBJECT IDENTIFIER ::= { arrisEntSensorThreshMIB 2 }

		
		-- 1.3.6.1.4.1.4115.1.7.1.4.2.1
		entThreshCompliances OBJECT IDENTIFIER ::= { entThreshConformance 1 }

		
		-- 1.3.6.1.4.1.4115.1.7.1.4.2.1.1
		entThreshCompliance MODULE-COMPLIANCE
			STATUS current
			DESCRIPTION 
				"Description."
			MODULE -- this module
				MANDATORY-GROUPS { entThreshValueGroup }
			::= { entThreshCompliances 1 }

		
		-- 1.3.6.1.4.1.4115.1.7.1.4.2.2
		entThreshGroups OBJECT IDENTIFIER ::= { entThreshConformance 2 }

		
		-- 1.3.6.1.4.1.4115.1.7.1.4.2.2.1
		entThreshValueGroup OBJECT-GROUP
			OBJECTS { entLowerWarnThresh, entUpperWarnThresh, entUpperFatalThresh, entLowerFatalThresh }
			STATUS current
			DESCRIPTION 
				"Description."
			::= { entThreshGroups 1 }

		
	
	END